Skip to content
HeatAlgo

Heat pump sizingfrom the heat loss.

A power class from the heat loss, radiators checked at lower flow temperatures, three variants. Preliminary sizing - not a replacement for an installation design.

HeatAlgo - the heat pump sizing result with the chosen pump's output

What it is

Heat pump selection in HeatAlgo is a browser-based preliminary pump power sizing with room-by-room radiator analysis - for installers and homeowners. Enter the building and radiator data, compare 3 flow temperature scenarios and get the result as a PDF.

An oversized pump cycles.An undersized one falls short.

The power of a heat pump follows from the building's load, not from the floor area or a catalogue. Then comes the question of which radiators cope with a lower supply temperature - and what each variant costs.

Power from a rule of thumbkilowatts per square metre or from memory, without this building's load
The radiators are unknownnobody checked which of them work at a lower supply temperature
Variants nobody compares35, 45 or 55 °C of supply changes both the pump and the radiators - and they are rarely set side by side

How to sizethe pump.

1 / 6
Algo AI in HeatAlgo - a new conversation beside the heat loss result: check the project, upload a documentBuilding step in the heat pump sizing module - location, floor area, residents, electricity price and hot waterRooms in the heat pump module - the heat emitters in each room: underfloor heating, radiators or bothPreliminary heat pump sizing - flow temperature scenarios compared with SCOP and costsRoom-by-room radiator analysis - feasibility status at the selected flow temperatureHeat pump sizing PDF report - cover page and the result page with the recommended variant

Which radiatorsstay?Ask Algo AI.

Algo AI reads the sizing result and the room-by-room radiator check. Ask about a power class, a supply temperature or one room - it answers from your numbers. The sizing is preliminary and does not replace an installation design.

Meet Algo AI →
AlgoThis projectFeedback

Which radiators can stay at a 45 °C supply?

THINKING

In the check at 45 °C the living room, bedroom and kitchen are covered and the bathroom is about 30 % short. Keep those three; replace the bathroom radiator with a larger one, or compare the 50 °C variant - the table shows what it changes in SCOP and consumption.

Ask about a power class, a room or a variant…

Everything for the conversationabout a heat pump.

Heat pump sizing result in the HeatAlgo app - the chosen pump's output and how it was reached, step by step
Radiator analysis, room by room.

A clear answer for every room: the radiator stays or gets replaced. You see straight away where a low flow temperature is enough.

Three flow temperature scenarios side by side.

Compare 40 °C, 55 °C, and 60 °C along with each scenario's running cost. The client sees what a lower flow temperature changes.

10 power classes averaged from market data.

Characteristics averaged from data on 239 devices from 28 manufacturers. You pick a power class, not a specific model.

A PDF report with a modernisation plan.

Which radiators to replace, which pump, what cost - hand it to your client on the spot. All in one clear document.

Heating costs compared per year.

The current heating cost set against a heat pump, concrete figures per year, in zloty, euro or dollars. Numbers you can put in front of the client.

Runs in the browser, no installation.

Desktop, tablet, or phone, and the project saves automatically. You come back to it from any device.

HeatAlgo vssums on paper.

Traditional software

  • PriceA per-seat licence
  • InstallationDesktop (Windows)
  • TrainingWeeks
  • Radiator analysisLimited or none
  • PDF reportYes, complex
  • Power sizingVaries

HeatAlgofree

  • PriceFree forever, reports from €19
  • InstallationBrowser
  • TrainingNone
  • Radiator analysisRoom by room
  • PDF reportYes, simple and clear
  • Power sizing10 power classes, data from 239 devices
a free account · full results and PDF after purchaseSee the method: a reference house calculated in full →

Frequently asked questions

No. HeatAlgo gives you a preliminary pump sizing for client conversations. A full installation project requires a site visit, accurate measurements, and consideration of local conditions. You use HeatAlgo at the sales stage, and do the full project after the client decides.

Check a preliminary sizing today

Register, enter the building and radiator data, and get a PDF for your client conversation.

No payment card. Your projects and data stay in your account.