MVHR calculator for your home.

Enter the rooms and residents - see the airflows and the balance.

Unit design airflow

155 m³/h

That is 43 l/s.

Supply 155 m³/h, extract 150 m³/h. Extract raised by 5 m³/h to balance.

Example: 4 people, 4 roomsPolish standard PN-83/B-03430
↓ Supply↑ ExtractUnit: 155 m³/hRoom 162.5 m³/hRoom 240 m³/hRoom 327.5 m³/hRoom 425 m³/hKitchen72.3 m³/hBathroom51.7 m³/hWC31 m³/h
Added to balance
Rooms
RoomSet byAirflow
Kitchenair changes70 m³/h
BathroomPolish standard50 m³/h
WCPolish standard30 m³/h
Room 1air changes62.5 m³/h
Room 2people40 m³/h
Room 3air changes27.5 m³/h
Room 4air changes25 m³/h
Required by the Polish standard
130 m³/h
Night minimum
78 m³/h

Calculated to PN-83/B-03430 with amendment Az3:2000, the Polish standard for dwelling ventilation. It is not the UK rule: in England Approved Document F applies. Use the result as a reference only.

The air change rates, 20 m³/h a person and the 2.5 m height are our assumptions, not the standard's values for dwellings. Rooms are taken as on one level.

Design heat recovery for the whole house

These are the air flows, without ducts or a unit. Ducts, pressure and the unit: MVHR design online

See a sample report

Unit design airflow 155 m³/h.

  • 600+accounts
  • 10,000+m² calculated
  • 2,000+underfloor zones
  • 100+installers

How the airflow is calculated

RoomsresidentsPolish standardunit airflow

Calculated to PN-83/B-03430, a Polish standard, not UK Part F - a reference only.

Ducts and the unit, in the app.

The heat recovery module draws the ducts, sums the pressure and checks the unit.

See heat recovery ventilation →
The heat recovery module's result in the HeatAlgo app: the building's air balance and the airflow in every room