How to check radiators in HeatAlgo: setup, rooms, network and result

The Radiators module step by step: room loads from the heat loss calculation or an estimate, the flow temperature, the pipe network and the swap list.

Founder of HeatAlgo, author of the calculation engine to EN 12831 and EN 1264

The Radiators module answers one question: will the radiators in a house give each room the heat it needs at the water temperature you choose? That matters before a heat pump, because a heat pump runs cheapest at a low flow temperature. The wizard has five steps: Setup, Radiators, Rooms, Network and Result. What the module does is on the Radiators page.

Units in the US

An account created from the US starts in imperial units: the fields show square feet, °F, inches and Btu/h. You can switch in Settings. The calculation itself stays in SI units. Radiator sizes in this article are in millimeters, as the makers' datasheets print them, and the rating point 75/65/20 is in °C, as every datasheet gives it.

Step 1: Setup

In "What you are doing" you pick "Checking existing radiators" - the module tells you at what temperature they are enough and which to swap - or "Sizing new radiators" for a new house; then you also choose "New radiator type" and "New radiator height".

In "Water temperature" you set "Flow temperature" (from 86 °F (30 °C) to 176 °F (80 °C)) and "Flow-return difference". You choose both values, and both print beside the result.

The room loads are in "Module settings" (the gear). When the project has a heat loss calculation, "Take rooms and loads from Heat loss" brings in the rooms with their loads calculated to EN 12831-1; after a change there, use "Refresh from Heat loss". Without it the module estimates the loads from "Heated floor area", "Building insulation" and the temperatures, and the screen and the report say so: "An estimate from the floor area, not a calculation to EN 12831-1." Where these numbers come from is in Radiator output: where the numbers come from.

Step 2: Radiators

Here you describe the radiators that hang in the house once - the rooms then pick them from the list. The list is split by kind: "Panel radiators", "Towel rails", "Column and cast iron" and "Other". The plus beside a kind (e.g. "Add a panel radiator") opens the dialog: "Name", "Type" (for a panel 10, 11, 20, 21, 22 or 33), "Height" and "Length". You can also take a radiator from My library, and "Also save to my library" keeps it for your next projects.

Have the maker's datasheet? Tick "I have the radiator's datasheet" and type "Datasheet output at 75/65/20" and "Exponent n" - the radiator then says "datasheet". Without one a panel radiator's output is "typical": the median of several makers' datasheets for that type and height. A radiator with no datasheet output and no panel type is "assumed" - counted as a type 22 panel of its size. Algo AI adds radiators from a description, an old design or a photo - see A radiator from a photo.

Step 3: Rooms

Rooms from the heat loss calculation are already here; you add others with "Add a room". Each has "Name", "Area" and "Temperature" (empty means as the house). A "Typed load" beats the heat loss calculation and the estimate. Mark a room with no heating as "Unheated room"; when the Network step has floors, also pick its "Storey".

"Add a radiator" opens the dialog. In "Radiator" you pick one of the house's radiators from the Radiators step; "Its own size" opens "New radiator in this house", adds a new radiator to the house's list, and the row takes it. Then "Count" and "Wall space" - the longest radiator that fits there, which is the most a swap may be (an empty field counts as 2000 mm). In "Sizing new radiators" mode the module sizes new radiators and takes only the "Wall space" from the row. A radiator stored with its size only (an older project or one Algo added) reads "Described in this room only" with "Save as a type".

Step 4: Network (for the designer)

The radiator result does not need a network - if you only check radiators, go to the Result step. The designer calculates a two-pipe system here:

  1. "Add a storey" with its "Floor level" - the riser length comes from the difference.
  2. "Load the plan" (an image or a PDF, up to 25 MB) and "Set the scale". Without a plan you draw on a 1 m grid.
  3. Place "Heat source", "Junction", "Radiator", "UFH manifold" and "Separator" and join them with pipes - one line is a pair: flow and return. A manifold from this project's radiant floor heating takes its flow and loop drop from it ("From underfloor heating"). A radiator lies horizontal or vertical: "Direction" in its panel ("Horizontal", "Vertical"), the rotate handle or the O key - the drawings turn it too.
  4. Fill in "Designer's assumptions" - values the designer adopts, not from a standard - in "Module settings" (the gear); a floor keeps only its "Floor level". Without them no pipe is sized, and the note about a missing value opens the settings.

The pump head, the total flow and the index circuit are free. The pipe sizes and each valve's "Required Kv" come with the report.

Step 5: Result

At the top is one sentence about the whole house, e.g. "Your radiators heat the house at 126 °F (52 °C)." - the lowest flow temperature at which they are enough in every room - and how many rooms are short at the temperature from Setup. That is free: change the temperature and see how many rooms are then enough.

The report unlocks a card for every room: "Needed" beside what the radiators give at the chosen temperature, "Enough from" and "What to swap to" - the smallest change that is enough and fits the "Wall space". Under the result is the method line (the EN 442 characteristic, without mounting factors and without heat from pipes) and the sentence "A radiator check, not an installation design."

Downloads

On the Result step, "Download" opens one menu, "Downloads":

  • "PDF report" - the "Full", "Simple" and "Custom" versions, see PDF report: full or simple. Without a report you get the watermarked preview.
  • "Materials list (PDF)" and "Materials list (Excel)" - an enquiry for a wholesaler: radiators, valves, pipes and fittings, with no brands and no prices. Pipe in "Steel - existing" (steel already in the house) counts as rougher (PN-M-34034, Table I-1) and is not ordered, nor is its insulation; a tee or transition joining it to new pipe is.
  • "Drawings (PDF)" and "Drawings (DXF)" - plans and schematic, A3 1:50, once a network is drawn.

Without the module unlocked, the materials list and the drawings sit in the menu marked "In the full report".

Free account and the report

Free, you get the house's flow temperature, how many rooms are short and the pump head of the network. Every room and the radiator to swap to, the pipe sizes and valve Kv, and the PDF report, materials list and drawings come with a report - for the Radiators module or for the whole project. What is free in each module is in free plan and what a report unlocks, and the prices are on the pricing page.

A HeatAlgo report follows EN 12831-1 and EN 1264, not ACCA Manual J, and is not accepted for permits or rebates.

HeatAlgo newsletter

New guides, HeatAlgo product changes and offers - straight to your inbox. You confirm the sign-up with a link we send you.

Have a question or feedback?

I reply personally - usually within 24 hours.

Got a similar question? Check the FAQ below ↓

FAQ

Frequently asked questions

Do I need a heat loss calculation to check radiators?

No, but the result is then an estimate. When the project has a heat loss calculation, "Take rooms and loads from Heat loss" brings in the rooms and each room's load calculated to EN 12831-1. Without it the module estimates the loads from the heated floor area, the insulation and the temperatures, and the screen and the report say so: "An estimate from the floor area, not a calculation to EN 12831-1."

What do I see in the Radiators module with a free account?

The flow temperature at which your radiators heat the house, and how many rooms are short at the temperature you chose. Change the temperature and you see at once how many rooms are then enough. You can draw the pipe network for free and see the pump head. Every room with its balance, the "What to swap to" list, the pipe sizes, the valve Kv, the materials list and the drawings come with a report.

Why does a radiator say "typical"?

Because its output is not from its own datasheet but from the median of several makers' datasheets for that type and height. Tick "I have the radiator's datasheet" and type "Datasheet output at 75/65/20" and "Exponent n" - the radiator then says "datasheet".

Does the module calculate one-pipe or gravity systems?

No. The pipe network calculates two-pipe systems only, laid out as a tree from the heat source. The radiators' output at a chosen temperature does not depend on the pipes, so you can check it in any house.

Is the result a heating installation design?

No. For a homeowner it is a radiator check, not an installation design. For a designer the module gives calculations and drawings for a central heating installation design - the design itself is signed by a qualified designer.

Blog

See also

Help

Radiator output: where the numbers in the Radiators module come from

Where the Radiators module gets a radiator's output (datasheet, typical, assumed), how it converts it to your temperature and where room loads come from.

Help

A radiator from a photo: how Algo AI reads radiators from a photo, a design or a message

How Algo AI fills in radiators from a photo, an old heating design PDF or a message: what it reads, what you type and what happens to the photo.

Help

Full or Simple PDF report: a client version, choosing pages and columns

The "PDF report" window in every module: Full with everything, Simple for the client, and Custom, where you choose the pages, floors and columns step by step.

Help

Settings: company details, report logo, units, notifications and privacy

HeatAlgo settings: company details and the logo on reports, imperial or metric units, the display currency, email notifications and the assistant log switch.

Help

Subscription, invoices and payments: how to buy, cancel and find your invoice

Subscription, invoices and payments in HeatAlgo: how a purchase in dollars works, who issues the invoice, how to add a tax ID, and how to cancel or resume.

Help

Troubleshooting HeatAlgo: saving, version conflicts, emails, PDF, units, AI and the browser

Troubleshooting HeatAlgo: saving and version conflicts, emails that do not arrive, a PDF that will not generate, units, Algo, expired links and the browser.

Help

PDF reports and the printable floor plan: what they contain, how to download them and what the report number means

Where to download each module's PDF report, what is on the cover, preview versus full report, scaled floor plans, metric units in the PDF and failed PDFs.

Help

Projects in HeatAlgo: create, edit, search and delete

How to create, edit and delete projects in HeatAlgo: what a project is, what client details do, how to search with Ctrl+K and what the project view shows.

Help

Getting around the HeatAlgo app: Start, the side menu, the top bar and shortcuts

Getting around the HeatAlgo app: Start, the side menu, the top bar, settings and billing, the Ctrl+K dialog, the wizards, units and what works on a phone.

Help

Radiant floor heating FAQ: answers for the HeatAlgo module

Radiant floor heating FAQ: why a room is not calculated, a loop that is too long, loop flows and the spacing warning, PEX tubing nodes, the manifold and stories.

Help

Your HeatAlgo account: sign-up, sign-in, password, language and units

Account sign-in and password help: create a free account, confirm your email, sign in, reset your password, set language and units, and fix a blocked account.

Help

Heat loss calculator for a house: room-by-room heat loss in seven steps

The heat loss calculator for a house, room by room: the seven steps of HeatAlgo's EN 12831-1 module, from your documents and Algo to the result, in US units.

Help

Client form FAQ: setup, sending, corrections and bringing the data in

Client form FAQ: how to hide questions and add your own fields, how long the link works, reminders, what your client sees, corrections, acceptance and import.

Help

Heat pump sizing in HeatAlgo: from heat loss to a first sizing, step by step

Heat pump sizing in HeatAlgo, heating only: start from the heat loss calculation or by hand, add rooms and radiators, compare three variants, read the result.

Help

Data flows between modules: import from the heat loss calculation and the client form

Which modules take data from which, what the module start screen shows, how updates work after a change in the source and what the import leaves out.

Help

The free plan and what a report unlocks: credits, prices in dollars and the window for new PDF versions

The free plan and what a report unlocks: what you see for free, what a report costs in dollars, the 7-day window for new PDF versions and when a subscription pays off.

Create a free HeatAlgo account

Register and go from client data to a finished heating project in one place.