Data flows between modules: import from the heat loss calculation and the client form

Which modules take data from which, what the module start screen shows, how updates work after a change in the source and what the import leaves out.

Founder of HeatAlgo, author of the calculation engine to EN 12831 and EN 1264

In one project the modules do not live apart: the heat loss calculation feeds heat pump sizing, radiant floor heating and ventilation, and an accepted client form feeds all four. Nothing moves without asking - every time, you see what comes in and what gets overwritten. This article describes which way the data flows, the module start screen, updates after a change in the source, and what the import leaves out on purpose.

Which way the data flows

Data flows as a tree, always one way:

  • the client form - to the heat loss calculation (building data and the room list), to heat pump sizing (building parameters), to radiant floor heating (supply and return water temperatures, tubing), to ventilation (ventilation type, frost protection),
  • the heat loss calculation - to heat pump sizing (building, rooms, heat loss), to radiant floor heating (rooms with their heat loss, temperature, type and story), to ventilation (rooms with their geometry).

The radiant floor heating and ventilation modules write nothing back to the heat loss calculation. When a module has two sources, it offers the richer one first: for radiant floor heating and ventilation, the rooms from the heat loss calculation; for the heat pump, the heat loss calculation.

Data from building documents read by the Algo assistant comes in by another route - Algo proposes values straight into the module's fields, and you confirm them. That is described in Algo, the AI assistant. Algo can also read a whole set of building plans and fill the heat loss calculation from them - rooms, building elements, windows and doors. How that works is in the heat loss calculation guide.

Every module stores and passes metric values, and every calculation stays metric, to EN 12831-1 and EN 1264. On an imperial account each module shows the same values in feet, ft², °F and Btu/h - so an import never changes a number, only how it is displayed.

The module start screen

A module that has no data yet opens on a start screen with the "Start with Algo", "I'll fill it in myself" and "Guide" buttons. In the heat loss calculation, heat pump sizing and ventilation, a line with the source sits under the buttons, with three figures from it. On an imperial account, for example: "Ready to bring in - Heat loss calculation: 7 rooms · 1,534 ft² heated · 28,662 Btu/h load" (142.5 m² and 8.4 kW on a metric account). The "Bring it into this module" button on that line brings in the data and opens the wizard. If a second source is also available, an "Also available" line with that source and its figures sits below, with a "Use this instead" button. "I'll fill it in myself" skips the import.

When there is nothing to bring in, the line says why and links to where you can change that:

  • "This project has no heat loss calculation yet" - the button leads to the heat loss calculation,
  • "N rooms still need completing" - the heat loss calculation is unfinished; "Finish the heat loss calculation",
  • "The heat loss calculation needs corrections" - it has blocking issues; "Open the heat loss calculation",
  • "The client sent the form back - accept it to bring the data in" - the form is waiting for your acceptance,
  • "The client has not sent the form back yet" - the form is with the client.

On a free account the line shows totals; the heat loss of each room comes in with the full version of the project.

Updates after a change in the source

When the source changes after an import (you add a room in the heat loss calculation, for example), the module shows the "Heat loss calculation has changed" dialog the next time you open it, with the date of the previous import and a list of values: for fields, the current and the new value ("becomes"); for rooms, the counts of new, changed and removed ones. Values you edited yourself are marked "edited" with the warning "Your value will be overwritten". You check what to bring in ("Select all" / "Select none") and click "Bring in the ticked values". "Not now" postpones the question, and "Do not ask about this source" turns it off for this module.

You see the state of every source in the module settings under "Data sources": "up to date", "newer data available" or "declined", with the date of the last import and the "Bring in", "Bring in again" and "Restore" buttons (for a declined source). The "Clear data" button in a module also clears the remembered imports, so after clearing, the start screen with the source lines comes back.

Heat pump sizing and the calculated heat loss

In heat pump sizing, "Bring it into this module" brings in the heated area and the rooms (name, area, temperature) and stores each room's heat loss from the heat loss calculation. The heat pump sizing runs from that heat loss, not from the insulation class. The wizard has its usual four steps and every field stays editable. Bringing data in only adds: rooms added by hand stay, and the radiators and radiant floor heating entered in the rooms from the calculation stay too - only the name, area and temperature are overwritten. After changes in the heat loss calculation, the same "Heat loss calculation has changed" dialog works as in the other modules.

Older projects in which the heat pump was linked to the heat loss calculation switch to this way of working by themselves the first time you open them. If an older project has a different heat loss stored than the current calculation, the module shows the "The calculated heat loss has changed" dialog with the "Use the current load" and "Leave it as it is" buttons. Details in the article on heat pump sizing.

Radiant floor heating and rooms from the heat loss calculation

In radiant floor heating ("Underfloor heating" in the app), the rooms from the heat loss calculation come with their heat loss, temperature, type and story; the stories from the heat loss calculation are created automatically. After changes in the heat loss calculation the panel shows "The heat loss calculation has newer data" and the "Update data from the heat loss calculation?" dialog: the room data is overwritten with the heat loss results, rooms without loops can be moved to the right story, and rooms with drawn loops stay where they are. Manual changes in the overwritten rooms cannot be restored. How the module then uses each room's heat loss is in how to design radiant floor heating in HeatAlgo.

The heat loss calculation and ventilation: consistency checks

Ventilation reads the rooms from the heat loss calculation and writes nothing back. In turn, the heat loss calculation checks whether its losses agree with the designed ventilation: the ventilation type must be "Mechanical with heat recovery (MVHR)", the heat recovery efficiency assumed in the heat loss calculation is compared with the efficiency of the chosen heat recovery ventilator (HRV), and the supply and exhaust airflow in every room with the airflows from the ventilation module. The heat loss calculation shows the differences as remarks, with the values from both modules.

What the import leaves out on purpose

The import from the client form lists the skipped items with a reason - on the start screen, under the source line. The most common:

  • a window or door with no matching room,
  • hybrid ventilation - it has no equivalent in the heat loss calculation,
  • a supply temperature given for a mixed system (the form also lists radiators, so the value may not be the radiant floor circuit's) or outside 68 °F-131 °F (20-55 °C),
  • no usable temperature difference - then neither the supply nor the return temperature is imported,
  • a tubing size not on the module's list,
  • a range hood - the answer is about one room and the form does not say which,
  • an open-combustion appliance - the form asks about an outdoor air supply, while the standard asks about drawing air from the room,
  • declared airflows - ventilation derives them from the standard.

You enter everything skipped in the module by hand.

A HeatAlgo report follows EN 12831-1 and EN 1264, not ACCA Manual J, and is not accepted for permits or rebates.

HeatAlgo newsletter

New guides, HeatAlgo product changes and offers - straight to your inbox. You confirm the sign-up with a link we send you.

Have a question or feedback?

I reply personally - usually within 24 hours.

Got a similar question? Check the FAQ below ↓

FAQ

Frequently asked questions

Where do the heat pump, radiant floor and ventilation modules get their rooms from?

From the heat loss calculation in the same project. The module start screen shows a "Ready to bring in" line with the source and its figures, and the "Bring it into this module" button on that line brings in the rooms and their heat loss. "I'll fill it in myself" skips the import; you get back to the sources in the module settings under "Data sources".

What does the client form carry into the modules?

Into the heat loss calculation, the building data and the rooms; into heat pump sizing, the building parameters; into radiant floor heating, the supply and return water temperatures and the tubing; into ventilation, the ventilation type and the frost protection. You must first accept the form in the project - while it is with the client or waiting for your acceptance, the module start screen says so.

I changed something in the heat loss calculation - do the heat pump and radiant floor modules update by themselves?

Not without asking. The next time you open the module you see the "Heat loss calculation has changed" dialog with a list of values; you check the ones to overwrite and click "Bring in the ticked values". "Not now" postpones the question, and "Do not ask about this source" turns it off - you turn it back on in the module settings. Heat pump sizing works the same way: the room heat losses from the heat loss calculation are a stored copy there, which you update in this dialog.

Why were some form answers not imported?

The import lists the skipped items with a reason: a window with no matching room, hybrid ventilation, a supply temperature outside 68-131 °F (20-55 °C) or given for a mixed system, a tubing size not on the list, a range hood without a named room, declared airflows (ventilation derives them from the standard). You enter those values by hand.

Do the radiant floor heating or ventilation modules write anything back to the heat loss calculation?

No. Data flows one way: from the client form to the four modules, and from the heat loss calculation to heat pump sizing, radiant floor heating and ventilation. The heat loss calculation only checks that it agrees with the ventilation design and shows any differences as remarks to fix in the heat loss calculation.

Does an imported value change when I switch to imperial units?

No. The modules pass metric values between them, and the calculations stay metric, to EN 12831-1 and EN 1264. Switching units in Settings changes only what you see and type: the same room shows its area in ft² and its heat loss in Btu/h on an imperial account.

Blog

See also

Help

Settings: company details, report logo, units, notifications and privacy

HeatAlgo settings: company details and the logo on reports, imperial or metric units, the display currency, email notifications and the assistant log switch.

Help

Subscription, invoices and payments: how to buy, cancel and find your invoice

Subscription, invoices and payments in HeatAlgo: how a purchase in dollars works, who issues the invoice, how to add a tax ID, and how to cancel or resume.

Help

Troubleshooting HeatAlgo: saving, version conflicts, emails, PDF, units, AI and the browser

Troubleshooting HeatAlgo: saving and version conflicts, emails that do not arrive, a PDF that will not generate, units, Algo, expired links and the browser.

Help

PDF reports and the printable floor plan: what they contain, how to download them and what the report number means

Where to download each module's PDF report, what is on the cover, preview versus full report, scaled floor plans, metric units in the PDF and failed PDFs.

Help

Projects in HeatAlgo: create, edit, search and delete

How to create, edit and delete projects in HeatAlgo: what a project is, what client details do, how to search with Ctrl+K and what the project view shows.

Help

Getting around the HeatAlgo app: Start, the side menu, the top bar and shortcuts

Getting around the HeatAlgo app: Start, the side menu, the top bar, settings and billing, the Ctrl+K dialog, the wizards, units and what works on a phone.

Help

Radiant floor heating FAQ: answers for the HeatAlgo module

Radiant floor heating FAQ: why a room is not calculated, a loop that is too long, flow and spacing warnings, PEX tubing nodes, the manifold and stories.

Help

Your HeatAlgo account: sign-up, sign-in, password, language and units

Account sign-in and password help: create a free account, confirm your email, sign in, reset your password, set language and units, and fix a blocked account.

Help

Heat loss calculator for a house: room-by-room heat loss in seven steps

The heat loss calculator for a house, room by room: the seven steps of HeatAlgo's EN 12831-1 module, from your documents and Algo to the result, in US units.

Help

Client form FAQ: setup, sending, corrections and bringing the data in

Client form FAQ: how to hide questions and add your own fields, how long the link works, reminders, what your client sees, corrections, acceptance and import.

Help

Heat pump sizing in HeatAlgo: from heat loss to a first sizing, step by step

Heat pump sizing in HeatAlgo, heating only: start from the heat loss calculation or by hand, add rooms and radiators, compare three variants, read the result.